PMM Narda CA0010 Click Analyser CISPR 14-1, CISPR16-1-1

PMM Narda CA0010 Click Analyser CISPR 14-1, CISPR16-1-1

Introducing the PMM Narda CA0010, an innovative click analyzer designed to work seamlessly with the 9010F EMI FFT receiver. This powerful device enables you to perform various click analysis and measurements effortlessly.

The CA0010, in conjunction with the 9010F FFT EMI receiver, allows for four simultaneous measurements at frequencies of 150 kHz, 500 kHz, 1.4 MHz, and 30 MHz. It can be used as a standalone setup for compliant tests. When connected to a PC, the dedicated software provides a full trace with additional information such as IF and QP time diagrams for each channel, click graphs, and an offline Rewind-Play-Pause-Forward feature for flexible use.

With its unique internal click calibrator, the CA0010 can generate all the required signals to check the analyzer’s performance in compliance with CISPR 16-1-1 requirements. You can set parameters like click amplitude, duration, interval, repetition, and CISPR pulse amplitude. The CA0010’s internal click generator is fully compliant with CISPR 16-1-1, allowing you to self-calibrate the device or any other external click meter.

The CA0010 offers selectable operating modes including two rates/two upper quartiles, two rates/four upper quartiles, four rates/four upper quartiles, and single run/double run. It is fully compliant with CISPR 16-1-1:2015 Ed. 4, CISPR 14-1:2016 Ed. 6, and CENELEC standards (EN 55016-1-1 and EN 55014-1), making it suitable for all “click” existing standards.

Equipped with an internal 16 ampere LISN (with an option to connect an external one) and a switch operations counting unit, the CA0010 ensures accurate and reliable measurements. Its outstanding dynamic range and saturation control, provided by the CISPR compliant RF front end, guarantee precise results.

Category:

Key Features

 

  • Discontinuous disturbance (click) analysis
  • Four independent frequency channels measuring simultaneously
  • Each channel with embedded preselector, attenuator and preamplifierDesigned to fully match CISPR 16-1-1 and CISPR 14-1 Standards
  • Highly flexible selection of number of rates, quartiles and runs operating mode
  • Test duration reduced to the minimum theoretically achievable
  • Two built-in 16A Line Impedance Stabilization Networks (LISNs)
  • User port for driving any external LISNs
  • Embedded switch operation counting unit
  • CISPR 16-1-1 embedded click and pulse generator output for internal or external use
  • Autocheck and calibration
  • Stand alone or PC driven operations
  • Free PCA PMM Click Analysis software
  • Free PCG PMM Click Generation software
  • Full IF and QP history 500us resolution
  • Compact yet sturdy construction
  • 140 dBμV (2 W) maximum input level without damage

 

Application Notes